Error Code Brother DCP - L2511D - Download Driver Brother DCP-L2511D - Brother DCP-L2511D

 Error Code Brother DCP-L2511D-Download Driver Brother DCP-L2511D-Brother DCP-L2511D

Error Code Brother DCP-L2511D-Download Driver Brother DCP-L2511D-Brother DCP-L2511D

Brother DCP-L2511D Buy on Amazon

Download Service Manuals Brother DCP-L2511D

Download Driver Brother DCP-L2511D

brother dcp l2510d driver

brother dcp l2511d driver

brother dcp l2511d manual

brother dcp l2510d toner

brother dcp l2510d manual

brother dcp l2511d troubleshooting

brother dcp l2510d wifi setup

brother dcp l2510d review

brother dcp-l3551cdw datasheet

brother dcp-l3551cdw wifi setup

brother dcp-l3551cdw pdf

brother wireless all in one printer dcp-l3551cdw

brother dcp-l2535d toner

Manuals and User Guides for Brother DCP-L2511D. We have 2 Brother DCP-L2511D manuals available for free PDF download: Service Manual ; Table of Contents. 4 ...

Parts Catalog > Brother > DCP-L2511D > page 5

Fuser Unit Assy For Brother DCP L2510D L2511D L2512D L2510 L2511 L2512 Fuser Assembly D00KV3001 D00KUA001. US $82.12. Color: Voltage (220V). Voltage (220V).

Downloads & Drivers for DCP-L2510D

(DCP-L2511D). 10.3 kg / 22.7 lb. (except for DCP-L2530DW for LTN). TBD. (DCP-L2530DW for LTN). Weight w/o Carton and toner/drum. TBD. 9.2 kg / 20.3 lb.

Fits: Brother DCP-7090 DCP-7095D DCP-7190DN DCP-7195DW DCP-9030CDN Brother DCP-B7500D DCP-B7520DW DCP-B7530DN DCP-B7535DW Brother DCP-L2510D DCP-L2511D ...

Error Code List Brother DCP - L2511D

Code: 0102

Description:

ASIC error or motor driver error occurred.

Remedy:

1 Main PCB failure Replace the main PCB ASSY.

Code: 0201

Description:

Cannot detect the synchronized signal of the paper feed motor. The speed of the paper feed motor does not stabilize within the specified time.

Remedy:

1 Connection failure of the paper feed motor flat cable Reconnect the paper feed motor flat cable. 2 Connection failure of the lowvoltage power supply PCB harness Reconnect the low-voltage power supply PCB harness. 3 Paper feed motor flat cable failure Replace the paper feed motor flat cable. 4 Damaged parts in main drive Replace the frame L unit. 5 Damaged fuser unit Replace the fuser unit. 6 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY. 7 Main PCB failure Replace the main PCB ASSY.

Code: 0300

Description:

Cannot detect the lock signal of the polygon motor for the laser unit. (second time)

Remedy:

1 Connection failure of the polygon motor harness Reconnect the polygon motor harness. 2 Laser unit failure Replace the laser unit. 3 Main PCB failure Replace the main PCB ASSY.

Code: 0305

Description:

Cannot detect the lock signal of the polygon motor for the laser unit. (first time)

Remedy:

1 Connection failure of the polygon motor harness Reconnect the polygon motor harness. 2 Laser unit failure Replace the laser unit. 3 Main PCB failure Replace the main PCB ASSY.

Code: 0401

Description:

BD sensor failure (second time)

Remedy:

<User Check> • There is a possibility of condensation. Leave the front and back cover open for at least 30 minutes when the power is ON. Close those covers and turn the power switch OFF and then back ON again.

1 Connection failure of the laser unit flat cable Reconnect the laser unit flat cable. 2 Laser unit failure Replace the laser unit. 3 Main PCB failure Replace the main PCB ASSY.

Code: 0405

Description:

BD sensor failure (first time)

Remedy:

<User Check> • There is a possibility of condensation. Leave the front and back cover open for at least 30 minutes when the power is ON. Close those covers and turn the power switch OFF and then back ON again.

1 Connection failure of the laser unit flat cable Reconnect the laser unit flat cable. 2 Laser unit failure Replace the laser unit. 3 Main PCB failure Replace the main PCB ASSY.

Code: 0501

Description:

The center thermistor of the fuser unit has not reached the specified temperature within the specified time.

Remedy:

<User Check> • Turn OFF the power switch. After several seconds, turn ON the power again and check that this error is reset.

1 Connection failure of the center or side thermistor harness of the fuser unit Reconnect the center or side thermistor harness of the fuser unit. 2 Connection failure of the heater harness of the fuser unit Reconnect the heater harness of the fuser unit. 3 Connection failure of the eject sensor PCB harness Reconnect the eject sensor PCB harness. 4 Connection failure of the lowvoltage power supply PCB harness Reconnect the low-voltage power supply PCB harness. 5 Eject sensor PCB failure Replace the eject sensor PCB ASSY. 6 Fuser unit failure Replace the fuser unit. 7 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY. 8 Main PCB failure Replace the main PCB ASSY.

Code: 0502

Description:

The center thermistor of the fuser unit has not reached the specified temperature within the specified time after it was heated normally to the certain level.

Remedy:

<User Check> • Turn OFF the power switch. After several seconds, turn ON the power again and check that this error is reset.

1 Connection failure of the center or side thermistor harness of the fuser unit Reconnect the center or side thermistor harness of the fuser unit. 2 Connection failure of the heater harness of the fuser unit Reconnect the heater harness of the fuser unit. 3 Connection failure of the eject sensor PCB harness Reconnect the eject sensor PCB harness. 4 Connection failure of the lowvoltage power supply PCB harness Reconnect the low-voltage power supply PCB harness. 5 Eject sensor PCB failure Replace the eject sensor PCB ASSY. 6 Fuser unit failure Replace the fuser unit. 7 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY. 8 Main PCB failure Replace the main PCB ASSY.

Code: 0503

Description:

The center thermistor of the fuser unit detected a temperature higher than the specified value.

Remedy:

<User Check> • Turn OFF the power switch. After several seconds, turn ON the power again and check that this error is reset.

1 Connection failure of the center or side thermistor harness of the fuser unit Reconnect the center or side thermistor harness of the fuser unit. 2 Connection failure of the heater harness of the fuser unit Reconnect the heater harness of the fuser unit. 3 Connection failure of the eject sensor PCB harness Reconnect the eject sensor PCB harness. 4 Connection failure of the lowvoltage power supply PCB harness Reconnect the low-voltage power supply PCB harness. 5 Eject sensor PCB failure Replace the eject sensor PCB ASSY. 6 Fuser unit failure Replace the fuser unit. 7 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY. 8 Main PCB failure Replace the main PCB ASSY.

Code: 0504

Description:

After the heat unit was heated normally, the center thermistor of the fuser unit detected a temperature lower than the specified value.

Remedy:

<User Check> • Turn OFF the power switch. After several seconds, turn ON the power again and check that this error is reset.

1 Connection failure of the center or side thermistor harness of the fuser unit Reconnect the center or side thermistor harness of the fuser unit. 2 Connection failure of the heater harness of the fuser unit Reconnect the heater harness of the fuser unit. 3 Connection failure of the eject sensor PCB harness Reconnect the eject sensor PCB harness. 4 Connection failure of the lowvoltage power supply PCB harness Reconnect the low-voltage power supply PCB harness. 5 Eject sensor PCB failure Replace the eject sensor PCB ASSY. 6 Fuser unit failure Replace the fuser unit. 7 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY. 8 Main PCB failure Replace the main PCB ASSY.

Code: 0505

Description:

The center thermistor of the fuser unit detected a temperature rise greater than the specified value within the specified time.

Remedy:

<User Check> • Turn OFF the power switch. After several seconds, turn ON the power again and check that this error is reset.

1 Connection failure of the center or side thermistor harness of the fuser unit Reconnect the center or side thermistor harness of the fuser unit. 2 Connection failure of the heater harness of the fuser unit Reconnect the heater harness of the fuser unit. 3 Connection failure of the eject sensor PCB harness Reconnect the eject sensor PCB harness. 4 Connection failure of the lowvoltage power supply PCB harness Reconnect the low-voltage power supply PCB harness. 5 Eject sensor PCB failure Replace the eject sensor PCB ASSY. 6 Fuser unit failure Replace the fuser unit. 7 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY. 8 Main PCB failure Replace the main PCB ASSY.

Code: 0506

Description:

The center thermistor of the fuser unit detected a temperature fall greater than the specified value within the specified time.

Remedy:

<User Check> • Turn OFF the power switch. After several seconds, turn ON the power again and check that this error is reset.

1 Connection failure of the center or side thermistor harness of the fuser unit Reconnect the center or side thermistor harness of the fuser unit. 2 Connection failure of the heater harness of the fuser unit Reconnect the heater harness of the fuser unit. 3 Connection failure of the eject sensor PCB harness Reconnect the eject sensor PCB harness. 4 Connection failure of the lowvoltage power supply PCB harness Reconnect the low-voltage power supply PCB harness. 5 Eject sensor PCB failure Replace the eject sensor PCB ASSY. 6 Fuser unit failure Replace the fuser unit. 7 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY. 8 Main PCB failure Replace the main PCB ASSY.

Code: 0508

Description:

Temperature of the end part didn’t rise by 1 °C when the fuser unit heater was turned ON.

Remedy:

<User Check> • Turn OFF the power switch. After several seconds, turn ON the power again and check that this error is reset.

1 Connection failure of the center or side thermistor harness of the fuser unit Reconnect the center or side thermistor harness of the fuser unit. 2 Connection failure of the heater harness of the fuser unit Reconnect the heater harness of the fuser unit. 3 Connection failure of the eject sensor PCB harness Reconnect the eject sensor PCB harness. 4 Connection failure of the lowvoltage power supply PCB harness Reconnect the low-voltage power supply PCB harness. 5 Eject sensor PCB failure Replace the eject sensor PCB ASSY. 6 Fuser unit failure Replace the fuser unit. 7 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY. 8 Main PCB failure Replace the main PCB ASSY.

Code: 050A

Description:

The hardware detected a temperature error through the center thermistor or the side thermistor of the fuser unit.

Remedy:

<User Check> • Turn OFF the power switch. After several seconds, turn ON the power again and check that this error is reset.

1 Connection failure of the center or side thermistor harness of the fuser unit Reconnect the center or side thermistor harness of the fuser unit. 2 Connection failure of the heater harness of the fuser unit Reconnect the heater harness of the fuser unit. 3 Connection failure of the eject sensor PCB harness Reconnect the eject sensor PCB harness. 4 Connection failure of the lowvoltage power supply PCB harness Reconnect the low-voltage power supply PCB harness. 5 Eject sensor PCB failure Replace the eject sensor PCB ASSY. 6 Fuser unit failure Replace the fuser unit. 7 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY. 8 Main PCB failure Replace the main PCB ASSY.

Code: 050B

Description:

When the center thermistor of the fuser unit was lower than the idle temperature, the side thermistor detected a temperature higher than the specified temperature.

Remedy:

<User Check> • Turn OFF the power switch. After several seconds, turn ON the power again and check that this error is reset.

1 Connection failure of the center or side thermistor harness of the fuser unit Reconnect the center or side thermistor harness of the fuser unit. 2 Connection failure of the heater harness of the fuser unit Reconnect the heater harness of the fuser unit. 3 Connection failure of the eject sensor PCB harness Reconnect the eject sensor PCB harness. 4 Connection failure of the lowvoltage power supply PCB harness Reconnect the low-voltage power supply PCB harness. 5 Eject sensor PCB failure Replace the eject sensor PCB ASSY. 6 Fuser unit failure Replace the fuser unit. 7 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY. 8 Main PCB failure Replace the main PCB ASSY.

Code: 050C

Description:

When the center thermistor of the fuser unit was higher than the idle temperature, the side thermistor detected a temperature lower than the specified temperature.

Remedy:

<User Check> • Turn OFF the power switch. After several seconds, turn ON the power again and check that this error is reset.

1 Connection failure of the center or side thermistor harness of the fuser unit Reconnect the center or side thermistor harness of the fuser unit. 2 Connection failure of the heater harness of the fuser unit Reconnect the heater harness of the fuser unit. 3 Connection failure of the eject sensor PCB harness Reconnect the eject sensor PCB harness. 4 Connection failure of the lowvoltage power supply PCB harness Reconnect the low-voltage power supply PCB harness. 5 Eject sensor PCB failure Replace the eject sensor PCB ASSY. 6 Fuser unit failure Replace the fuser unit. 7 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY. 8 Main PCB failure Replace the main PCB ASSY.

Code: 0900

Description:

Detected irregular power supply for more than 100 times.

Remedy:

1 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY. Refer to “Reset irregular power supply detection counter of low-voltage power supply PCB (Function code 88)” to reset the irregular power supply detection counter after the replacement. 2 Main PCB failure Replace the main PCB ASSY.

Note: The irregular power supply detection error (Error code 0900) of the low-voltage power supply PCB occurs when there is a large distortion in the power supply voltage supplied to the machine. In this case, if the same power supply is used, the same error might occur again even if the low-voltage power supply PCB ASSY is replaced. For this reason, be sure to ask the user to rearrange the installation environment.

Code: 0A02

Description:

Detected a fan failure.

Remedy:

1 Connection failure of the fan harness Reconnect the fan harness. 2 Connection failure of the highvoltage power supply PCB harness Reconnect the high-voltage power supply PCB harness. 3 Fan failure Replace the fan. 4 High-voltage power supply PCB failure Replace the high-voltage power supply PCB ASSY. 5 Main PCB failure Replace the main PCB ASSY.

Code: 0B01

Description:

An error occurred in the high-voltage power supply PCB ASSY while operating.

Remedy:

<User Check> • Slide the green tab of the drum unit to left and right for two to three times to clean the corona wire. • There is a possibility of condensation. Leave the front and back cover open for at least 30 minutes when the power is ON. Close those covers and turn the power switch OFF and then back ON again.

1 Dirt on the machine, the drum unit, the toner cartridge and the toner box terminal Clean the machine, the drum unit, the toner cartridge and the toner box terminal. 2 Connection failure of the highvoltage power supply PCB harness Reconnect the high-voltage power supply PCB harness. 3 High-voltage power supply PCB failure Replace the high-voltage power supply PCB ASSY. 4 Main PCB failure Replace the main PCB ASSY.

Code: 0B02

Description:

An error occurred in the high-voltage power supply PCB ASSY when the machine was in the ready state.

Remedy:

<User Check> • Slide the green tab of the drum unit to left and right for two to three times to clean the corona wire. • There is a possibility of condensation. Leave the front and back cover open for at least 30 minutes when the power is ON. Close those covers and turn the power switch OFF and then back ON again.

1 Dirt on the machine, the drum unit, the toner cartridge and the toner box terminal Clean the machine, the drum unit, the toner cartridge and the toner box terminal. 2 Connection failure of the highvoltage power supply PCB harness Reconnect the high-voltage power supply PCB harness. 3 High-voltage power supply PCB failure Replace the high-voltage power supply PCB ASSY. 4 Main PCB failure Replace the main PCB ASSY.

Code: 2200

Description:

Cartridge sensor detected that the incompatible toner cartridge was installed.

Remedy:

<User Check> • Replace with a toner cartridge which has a correspondent capacity.

1 Main PCB failure Replace the main PCB ASSY.

Code: 2400

Description:

Toner cartridge is not recognized by the cartridge sensor.

Remedy:

<User Check> • Replace with a toner cartridge which has a correspondent capacity.

1 Main PCB failure Replace the main PCB ASSY.

Code: 2500

Description:

Toner cartridge could not communicate with the cartridge sensor.

Remedy:

<User Check> • Replace with a toner cartridge which has a correspondent capacity.

1 Main PCB failure Replace the main PCB ASSY.

Code: 2E00

Description:

Could not communicate with the cartridge sensor on the machine side.

Remedy:

<User Check> • Replace with a toner cartridge which has a correspondent capacity.

1 Main PCB failure Replace the main PCB ASSY.

Code: 3A00

Description:

A communication error occurred between the controller and engine in main PCB.

Remedy:

1 Main PCB failure Replace the main PCB ASSY.

Code: 4000

Description:

Number of the drum unit rotations reaches the upper limit soon.

Remedy:

<User Check> • Prepare a new drum unit.

1 If the error display is not cleared after the drum unit in the toner box model has been replaced with a new one. Refer to “Resetting Drum Counter” and perform the manual new drum detection. 2 Replace the drum unit with a new one and reset the drum counter. If the error display is not cleared, the main PCB is faulty. Replace the main PCB ASSY.

Code: 4200

Description:

Number of the drum unit rotations has reached the upper limit. (Printing does not stop.)

Remedy:

<User Check> • Prepare a new drum unit.

1 If the error display is not cleared after the drum unit in the toner box model has been replaced with a new one. Refer to “Resetting Drum Counter” and perform the manual new drum detection. 2 Replace the drum unit with a new one and reset the drum counter. If the error display is not cleared, the main PCB is faulty. Replace the main PCB ASSY.

Code: 4B01

Description:

Dot counter of the toner cartridge or develop roller counter reaches the upper limit soon.

Remedy:

<User Check> • Prepare a new toner cartridge.

1 Main PCB failure Replace the main PCB ASSY.

Code: 4B06

Description:

The amount of toner supplied of the toner box reaches the upper limit soon.

Remedy:

<User Check> • Prepare a new toner cartridge.

1 Main PCB failure Replace the main PCB ASSY.

Code: 4C01

Description:

Dot count or develop roller counter of the toner cartridge in models without toner box has reached the upper limit in the toner stop mode.

Remedy:

<User Check> • Replace the toner cartridge whose counter reached the upper limit.

1 Replace the toner cartridge or toner box with a new one and reset the toner counter. If the error display is not cleared, the main PCB is faulty. Replace the main PCB ASSY.

Code: 4C06

Description:

The amount of toner supplied of the toner box has reached the upper limit.

Remedy:

<User Check> • Replace the toner cartridge whose counter reached the upper limit.

1 Replace the toner cartridge or toner box with a new one and reset the toner counter. If the error display is not cleared, the main PCB is faulty. Replace the main PCB ASSY.

Code: 4D01

Description:

Dot count or develop roller counter of the toner cartridge in models without toner box is reaching the upper limit in the continuous printing mode.

Remedy:

<User Check> • Replace the toner cartridge whose counter reached the upper limit.

1 Replace the toner cartridge or toner box with a new one and reset the toner counter. If the error display is not cleared, the main PCB is faulty. Replace the main PCB ASSY.

Code: 4E01

Description:

Toner cartridge in models without toner box has reached the upper limit in the continuous printing mode.

Remedy:

<User Check> • Replace the toner cartridge whose counter reached the upper limit.

1 Replace the toner cartridge or toner box with a new one and reset the toner counter. If the error display is not cleared, the main PCB is faulty. Replace the main PCB ASSY.

Code: 4F01

Description:

The new toner sensor of the toner cartridge could not detect a new cartridge properly.

Remedy:

<User Check> • Replace the toner cartridge with a new toner cartridge again. • If the machine is on the uneven surface, place it on a level surface.

1 Connection failure of the new toner sensor PCB harness Reconnect the new toner sensor PCB harness. 2 New toner actuator coming off or caught in some sections of the machine Reattach the new toner actuator. 3 New toner sensor failure Replace the new toner sensor PCB ASSY. 4 Main PCB failure Replace the main PCB ASSY.

Code: 4F05

Description:

New process sensor could not detect the new drum unit correctly.

Remedy:

<User Check> • Replace the drum unit with a new drum unit again. • If the machine is on the uneven surface, place it on a level surface.

1 High-voltage power supply PCB failure Replace the high-voltage power supply PCB ASSY. 2 Main PCB failure Replace the main PCB ASSY.

Code: 5E00

Description:

New toner box sensor could not detect the new toner box correctly.

Remedy:

<User Check> • Replace the toner box with a new toner box again. • If the machine is on the uneven surface, place it on a level surface.

1 New toner box sensor failure Replace the high-voltage power supply PCB ASSY. 2 Main PCB failure Replace the main PCB ASSY.

Code: 6001

Description:
The front cover sensor detected that the front cover was open.
Remedy:
<User Check> • Close the front cover.
1 Connection failure of the front cover sensor harness Reconnect the front cover sensor harness. 2 Front cover failure Replace the front cover. 3 Front cover sensor failure Replace the front cover sensor. 4 Main PCB failure Replace the main PCB ASSY.

Code: 6004

Description:
The eject sensor detected that the fuser cover was open.
Remedy:
<User Check> • Close the fuser cover.
1 Eject actuator coming off or caught in some sections of the machine Reattach the eject actuator. 2 Fuser cover attachment failure Reattach the fuser cover. 3 Connection failure of the eject sensor PCB harness Reconnect the eject sensor PCB harness. 4 Eject sensor PCB failure Replace the eject sensor PCB ASSY. 5 Main PCB failure Replace the main PCB ASSY.

Code: 6101

Description:
The new toner sensor detected that no toner cartridge was set.
Remedy:
<User Check> • Set the toner cartridge correctly.
1 New toner sensor PCB failure Replace the new toner sensor PCB ASSY. 2 High-voltage power supply PCB failure Replace the high-voltage power supply PCB ASSY. 3 Main PCB failure Replace the main PCB ASSY.

Code: 6106

Description:
The new toner box sensor detected that no toner box was set.
Remedy:
<User Check> • Set the toner box correctly.
1 New toner box actuator coming off or caught in some sections of the machine Reattach the new toner box actuator. 2 New toner box sensor failure Replace the high-voltage power supply PCB ASSY. 3 Main PCB failure Replace the main PCB ASSY.

Code: 6200

Description:
Detected that the drum unit was not set by detecting the electrodes current.
Remedy:
<User Check> • Set the drum unit correctly.
1 Dirt on the electrodes of the drum unit and those of the machine Clean the electrodes of the drum unit and those of the machine. 2 Dirt on the high-voltage power supply PCB terminal Clean the high-voltage power supply PCB terminal. 3 High-voltage power supply PCB failure Replace the high-voltage power supply PCB ASSY. 4 Main PCB failure Replace the main PCB ASSY.

Code: 6801

Description:
The side thermistor detected a temperature higher than the specified value.
Remedy:
<User Check> • Lower the room temperature. • Keep the machine away from heating appliances. • Check that the fan is not clogged.
1 Connection failure of the side thermistor harness Reconnect the side thermistor harness. 2 Fuser unit thermistor failure Replace the fuser unit. 3 Main PCB failure Replace the main PCB ASSY.

Code: 6901

Description:
Some fuser unit errors occurred at power-ON or upon recovery from sleep mode.
Remedy:
1 Connection failure of a fuser unit harness Reconnect the fuser unit harness. 2 Connection failure of the eject sensor PCB harness Reconnect the eject sensor PCB harness. 3 Fuser unit failure Replace the fuser unit. 4 Eject sensor PCB failure Replace the eject sensor PCB ASSY. 5 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY. 6 Main PCB failure Replace the main PCB ASSY.
Note: • Turn OFF the power switch. After the fuser unit has cooled sufficiently, turn ON the power switch again and leave the machine for 15 minutes. This problem may then be cleared. • To release the fuser unit error after taking appropriate measures, enter the maintenance mode once and quit it with the function code 99.

Code: 6902

Description:
After the error was detected at the fuser unit, power was turned ON again and the error is being checked. (If power is turned OFF and ON after error code 6901 occurred, this code is displayed for about 15 minutes.)
Remedy:
1 Connection failure of a fuser unit harness Reconnect the fuser unit harness. 2 Connection failure of the eject sensor PCB harness Reconnect the eject sensor PCB harness. 3 Fuser unit failure Replace the fuser unit. 4 Eject sensor PCB failure Replace the eject sensor PCB ASSY. 5 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY. 6 Main PCB failure Replace the main PCB ASSY.
Note: • Turn OFF the power switch. After the fuser unit has cooled sufficiently, turn ON the power switch again and leave the machine for 15 minutes. This problem may then be cleared. • To release the fuser unit error after taking appropriate measures, enter the maintenance mode once and quit it with the function code 99.

Code: 6A00

Description:
Electric discharge that may be caused by dirt on the corona wire of the drum unit was detected.
Remedy:
<User Check> • Slide the green tab of the drum unit to left and right for two to three times to clean the corona wire. • Clean the electrode of the drum unit. • Replace the drum unit.
1 Dirt on the electrodes of the machine Clean the electrodes of the machine. 2 Dirt on the high-voltage power supply PCB terminal Clean the high-voltage power supply PCB terminal. 3 High-voltage power supply PCB failure Replace the high-voltage power supply PCB ASSY. 4 Main PCB failure Replace the main PCB ASSY.

Code: 6F00

Description:
Detected that supply power is unstable. (less than 100 times)
Remedy:
<User Check> • Turn the power switch OFF and then back ON again. • Use a noise filter on the power supply.
1 The power supply waveform is incorrect Install a voltage stabilizer in the power supply part.

Code: 7000

Description:
After the registration rear sensor detects paper pass, the eject sensor does not detect paper pass.
Remedy:
<User Check> • Remove the jammed paper.
1 Foreign object inside the machine Remove the foreign object. 2 Eject actuator coming off or caught in some sections of the machine Reattach the eject actuator. 3 Fuser cover attachment failure Reattach the fuser cover. 4 Connection failure of the eject sensor PCB harness Reconnect the eject sensor PCB harness. 5 Damaged fuser drive gear 64R/ 36R Replace the fuser drive gear 64R/36R. 6 Damaged gears in the paper feed drive system Replace the frame L unit. 7 Eject sensor failure Replace the eject sensor PCB ASSY. 8 Fuser unit failure Replace the fuser unit. 9 Main PCB failure Replace the main PCB ASSY.

Code: 7100

Description:
After the registration rear sensor detects the end of paper pass and the specified period of time has passed, the eject sensor continues to detect paper pass.
Remedy:
<User Check> • Remove the jammed paper. • Check if the back cover is open during duplex printing.
1 Foreign object in the rear of the machine Remove the foreign object. 2 Eject actuator caught in some sections of the machine Reattach the eject actuator. 3 Fuser cover attachment failure Reattach the fuser cover. 4 Back cover attachment failure Reattach the back cover. 5 Eject sensor failure Replace the eject sensor PCB ASSY. 6 Back cover failure Replace the back cover. 7 Damaged fuser drive gear 64R/36R Replace the fuser drive gear 64R/36R. 8 Damaged gears in the paper feed drive system Replace the frame L unit. 9 Fuser unit failure Replace the fuser unit. 10 Main PCB failure Replace the main PCB ASSY.

Code: 7200

Description:
When the paper is fed from the MP tray, after the MP paper empty sensor detects paper pass, the registration rear sensor does not detect paper pass after a set period of time.
Remedy:
<User Check> • Remove the jammed paper. • Add the paper properly using the MP tray paper guide. • Check if the papers loaded in the MP tray is not held down with your hand. • Check if the double feed occurs in the MP tray. • Close the front cover correctly.
1 Foreign object in the rear of the machine Remove the foreign object. 2 Registration rear actuator coming off or caught in some sections of the machine Reattach the registration rear actuator. 3 Connection failure of the registration front/rear sensor PCB harness Reconnect the registration front/rear sensor PCB harness. 4 Registration rear sensor failure Replace the actuator holder ASSY. 5 Damaged gears in the paper feed drive system Replace the frame L unit. 6 Main PCB failure Replace the main PCB ASSY.

Code: 7302

Description:
When printing from the paper tray, the registration front sensor does not detect paper pass within the specified time after the T1 paper feed sensor detected paper pass.
Remedy:
<User Check> • Remove the jammed paper. • Add the paper properly using the paper guide of paper tray.
1 Foreign object in the front of the machine Remove the foreign object. 2 Registration front actuator attachment failure Reattach the registration front actuator. 3 Connection failure of the registration front/rear sensor harness Reconnect the registration front/rear sensor harness. 4 Registration front/rear sensor PCB failure Replace the actuator holder ASSY. 5 Damaged gears in the paper feed drive system Replace the frame L unit. 6 Main PCB failure Replace the main PCB ASSY.

Code: 7800

Description:
After the first side is printed in 2-sided printing mode, the registration front sensor does not detect paper pass after a set period of time.
Remedy:
<User Check> • Remove the jammed paper. • Close the back cover correctly.
1 Foreign object in the rear of the machine or duplex tray Remove the foreign object. 2 Gears in the paper feed system coming off Reattach the paper feed gear. 3 Duplex tray failure Replace the duplex tray. 4 Damaged gears in the paper feed drive system Replace the frame L unit. 5 Main PCB failure Replace the main PCB ASSY.

Code: 8903

Description:
The back cover sensor detected the open state when 2-sided printing is started (before the registration of printing in the engine).
Remedy:
<User Check> • Close the back cover correctly. • Check that the duplex tray is set correctly.
1 Duplex tray is not set correctly Reattach the duplex tray correctly. 2 Back cover sensor attachment failure Reattach the back cover sensor. 3 Breakage of boss that presses the back cover sensor Replace the back cover. 4 Guide which pushes the back cover sensor of the duplex tray is faulty Replace the duplex tray. 5 Back cover sensor failure Replace the eject sensor PCB ASSY. 6 Main PCB failure Replace the main PCB ASSY.

Code: 8904

Description:
The back cover sensor detected the open state during 2-sided printing (after the registration of printing in the engine).
Remedy:
<User Check> • Close the back cover correctly. • Check that the duplex tray is set correctly.
1 Duplex tray is not set correctly Reattach the duplex tray correctly. 2 Back cover sensor attachment failure Reattach the back cover sensor. 3 Breakage of boss that presses the back cover sensor Replace the back cover. 4 Guide which pushes the back cover sensor of the duplex tray is faulty Replace the duplex tray. 5 Back cover sensor failure Replace the eject sensor PCB ASSY. 6 Main PCB failure Replace the main PCB ASSY.

Code: 8A01

Description:
The registration rear sensor detected that the paper fed was smaller or larger than the specified size in duplex printing mode.
Remedy:
<User Check> • Use appropriate paper (Letter to Legal).
1 Registration rear actuator caught in some sections of the machine Reattach the registration rear actuator. 2 Registration rear sensor failure Replace the actuator holder ASSY. 3 Main PCB failure Replace the main PCB ASSY.

 

Post a Comment

0 Comments