Error Code Brother DCP-L2511D-Download Driver Brother DCP-L2511D-Brother DCP-L2511D
Error Code Brother DCP-L2511D-Download Driver Brother DCP-L2511D-Brother DCP-L2511D |
Brother DCP-L2511D Buy on Amazon
Download Service Manuals Brother DCP-L2511D
Download Driver Brother DCP-L2511D
brother dcp l2510d driver
brother dcp l2511d driver
brother dcp l2511d manual
brother dcp l2510d toner
brother dcp l2510d manual
brother dcp l2511d troubleshooting
brother dcp l2510d wifi setup
brother dcp l2510d review
brother dcp-l3551cdw datasheet
brother dcp-l3551cdw wifi setup
brother dcp-l3551cdw pdf
brother wireless all in one printer dcp-l3551cdw
brother dcp-l2535d toner
Manuals and User Guides for Brother DCP-L2511D. We have 2 Brother DCP-L2511D manuals available for free PDF download: Service Manual ; Table of Contents. 4 ...
Parts Catalog > Brother > DCP-L2511D > page 5
Fuser Unit Assy For Brother DCP L2510D L2511D L2512D L2510 L2511 L2512 Fuser Assembly D00KV3001 D00KUA001. US $82.12. Color: Voltage (220V). Voltage (220V).
Downloads & Drivers for DCP-L2510D
(DCP-L2511D). 10.3 kg / 22.7 lb. (except for DCP-L2530DW for LTN). TBD. (DCP-L2530DW for LTN). Weight w/o Carton and toner/drum. TBD. 9.2 kg / 20.3 lb.
Fits: Brother DCP-7090 DCP-7095D DCP-7190DN DCP-7195DW DCP-9030CDN Brother DCP-B7500D DCP-B7520DW DCP-B7530DN DCP-B7535DW Brother DCP-L2510D DCP-L2511D ...
Error Code List Brother DCP - L2511D
Code: 0102
Description:
ASIC error or motor driver error occurred.
Remedy:
1 Main PCB failure Replace the main PCB ASSY.
Code: 0201
Description:
Cannot detect the synchronized signal of the paper feed motor. The speed of the paper feed motor does not stabilize within the specified time.
Remedy:
1 Connection failure of the paper feed motor flat cable Reconnect the paper feed motor flat cable. 2 Connection failure of the lowvoltage power supply PCB harness Reconnect the low-voltage power supply PCB harness. 3 Paper feed motor flat cable failure Replace the paper feed motor flat cable. 4 Damaged parts in main drive Replace the frame L unit. 5 Damaged fuser unit Replace the fuser unit. 6 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY. 7 Main PCB failure Replace the main PCB ASSY.
Code: 0300
Description:
Cannot detect the lock signal of the polygon motor for the laser unit. (second time)
Remedy:
1 Connection failure of the polygon motor harness Reconnect the polygon motor harness. 2 Laser unit failure Replace the laser unit. 3 Main PCB failure Replace the main PCB ASSY.
Code: 0305
Description:
Cannot detect the lock signal of the polygon motor for the laser unit. (first time)
Remedy:
1 Connection failure of the polygon motor harness Reconnect the polygon motor harness. 2 Laser unit failure Replace the laser unit. 3 Main PCB failure Replace the main PCB ASSY.
Code: 0401
Description:
BD sensor failure (second time)
Remedy:
<User Check> • There is a possibility of condensation. Leave the front and back cover open for at least 30 minutes when the power is ON. Close those covers and turn the power switch OFF and then back ON again.
1 Connection failure of the laser unit flat cable Reconnect the laser unit flat cable. 2 Laser unit failure Replace the laser unit. 3 Main PCB failure Replace the main PCB ASSY.
Code: 0405
Description:
BD sensor failure (first time)
Remedy:
<User Check> • There is a possibility of condensation. Leave the front and back cover open for at least 30 minutes when the power is ON. Close those covers and turn the power switch OFF and then back ON again.
1 Connection failure of the laser unit flat cable Reconnect the laser unit flat cable. 2 Laser unit failure Replace the laser unit. 3 Main PCB failure Replace the main PCB ASSY.
Code: 0501
Description:
The center thermistor of the fuser unit has not reached the specified temperature within the specified time.
Remedy:
<User Check> • Turn OFF the power switch. After several seconds, turn ON the power again and check that this error is reset.
1 Connection failure of the center or side thermistor harness of the fuser unit Reconnect the center or side thermistor harness of the fuser unit. 2 Connection failure of the heater harness of the fuser unit Reconnect the heater harness of the fuser unit. 3 Connection failure of the eject sensor PCB harness Reconnect the eject sensor PCB harness. 4 Connection failure of the lowvoltage power supply PCB harness Reconnect the low-voltage power supply PCB harness. 5 Eject sensor PCB failure Replace the eject sensor PCB ASSY. 6 Fuser unit failure Replace the fuser unit. 7 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY. 8 Main PCB failure Replace the main PCB ASSY.
Code: 0502
Description:
The center thermistor of the fuser unit has not reached the specified temperature within the specified time after it was heated normally to the certain level.
Remedy:
<User Check> • Turn OFF the power switch. After several seconds, turn ON the power again and check that this error is reset.
1 Connection failure of the center or side thermistor harness of the fuser unit Reconnect the center or side thermistor harness of the fuser unit. 2 Connection failure of the heater harness of the fuser unit Reconnect the heater harness of the fuser unit. 3 Connection failure of the eject sensor PCB harness Reconnect the eject sensor PCB harness. 4 Connection failure of the lowvoltage power supply PCB harness Reconnect the low-voltage power supply PCB harness. 5 Eject sensor PCB failure Replace the eject sensor PCB ASSY. 6 Fuser unit failure Replace the fuser unit. 7 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY. 8 Main PCB failure Replace the main PCB ASSY.
Code: 0503
Description:
The center thermistor of the fuser unit detected a temperature higher than the specified value.
Remedy:
<User Check> • Turn OFF the power switch. After several seconds, turn ON the power again and check that this error is reset.
1 Connection failure of the center or side thermistor harness of the fuser unit Reconnect the center or side thermistor harness of the fuser unit. 2 Connection failure of the heater harness of the fuser unit Reconnect the heater harness of the fuser unit. 3 Connection failure of the eject sensor PCB harness Reconnect the eject sensor PCB harness. 4 Connection failure of the lowvoltage power supply PCB harness Reconnect the low-voltage power supply PCB harness. 5 Eject sensor PCB failure Replace the eject sensor PCB ASSY. 6 Fuser unit failure Replace the fuser unit. 7 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY. 8 Main PCB failure Replace the main PCB ASSY.
Code: 0504
Description:
After the heat unit was heated normally, the center thermistor of the fuser unit detected a temperature lower than the specified value.
Remedy:
<User Check> • Turn OFF the power switch. After several seconds, turn ON the power again and check that this error is reset.
1 Connection failure of the center or side thermistor harness of the fuser unit Reconnect the center or side thermistor harness of the fuser unit. 2 Connection failure of the heater harness of the fuser unit Reconnect the heater harness of the fuser unit. 3 Connection failure of the eject sensor PCB harness Reconnect the eject sensor PCB harness. 4 Connection failure of the lowvoltage power supply PCB harness Reconnect the low-voltage power supply PCB harness. 5 Eject sensor PCB failure Replace the eject sensor PCB ASSY. 6 Fuser unit failure Replace the fuser unit. 7 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY. 8 Main PCB failure Replace the main PCB ASSY.
Code: 0505
Description:
The center thermistor of the fuser unit detected a temperature rise greater than the specified value within the specified time.
Remedy:
<User Check> • Turn OFF the power switch. After several seconds, turn ON the power again and check that this error is reset.
1 Connection failure of the center or side thermistor harness of the fuser unit Reconnect the center or side thermistor harness of the fuser unit. 2 Connection failure of the heater harness of the fuser unit Reconnect the heater harness of the fuser unit. 3 Connection failure of the eject sensor PCB harness Reconnect the eject sensor PCB harness. 4 Connection failure of the lowvoltage power supply PCB harness Reconnect the low-voltage power supply PCB harness. 5 Eject sensor PCB failure Replace the eject sensor PCB ASSY. 6 Fuser unit failure Replace the fuser unit. 7 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY. 8 Main PCB failure Replace the main PCB ASSY.
Code: 0506
Description:
The center thermistor of the fuser unit detected a temperature fall greater than the specified value within the specified time.
Remedy:
<User Check> • Turn OFF the power switch. After several seconds, turn ON the power again and check that this error is reset.
1 Connection failure of the center or side thermistor harness of the fuser unit Reconnect the center or side thermistor harness of the fuser unit. 2 Connection failure of the heater harness of the fuser unit Reconnect the heater harness of the fuser unit. 3 Connection failure of the eject sensor PCB harness Reconnect the eject sensor PCB harness. 4 Connection failure of the lowvoltage power supply PCB harness Reconnect the low-voltage power supply PCB harness. 5 Eject sensor PCB failure Replace the eject sensor PCB ASSY. 6 Fuser unit failure Replace the fuser unit. 7 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY. 8 Main PCB failure Replace the main PCB ASSY.
Code: 0508
Description:
Temperature of the end part didn’t rise by 1 °C when the fuser unit heater was turned ON.
Remedy:
<User Check> • Turn OFF the power switch. After several seconds, turn ON the power again and check that this error is reset.
1 Connection failure of the center or side thermistor harness of the fuser unit Reconnect the center or side thermistor harness of the fuser unit. 2 Connection failure of the heater harness of the fuser unit Reconnect the heater harness of the fuser unit. 3 Connection failure of the eject sensor PCB harness Reconnect the eject sensor PCB harness. 4 Connection failure of the lowvoltage power supply PCB harness Reconnect the low-voltage power supply PCB harness. 5 Eject sensor PCB failure Replace the eject sensor PCB ASSY. 6 Fuser unit failure Replace the fuser unit. 7 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY. 8 Main PCB failure Replace the main PCB ASSY.
Code: 050A
Description:
The hardware detected a temperature error through the center thermistor or the side thermistor of the fuser unit.
Remedy:
<User Check> • Turn OFF the power switch. After several seconds, turn ON the power again and check that this error is reset.
1 Connection failure of the center or side thermistor harness of the fuser unit Reconnect the center or side thermistor harness of the fuser unit. 2 Connection failure of the heater harness of the fuser unit Reconnect the heater harness of the fuser unit. 3 Connection failure of the eject sensor PCB harness Reconnect the eject sensor PCB harness. 4 Connection failure of the lowvoltage power supply PCB harness Reconnect the low-voltage power supply PCB harness. 5 Eject sensor PCB failure Replace the eject sensor PCB ASSY. 6 Fuser unit failure Replace the fuser unit. 7 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY. 8 Main PCB failure Replace the main PCB ASSY.
Code: 050B
Description:
When the center thermistor of the fuser unit was lower than the idle temperature, the side thermistor detected a temperature higher than the specified temperature.
Remedy:
<User Check> • Turn OFF the power switch. After several seconds, turn ON the power again and check that this error is reset.
1 Connection failure of the center or side thermistor harness of the fuser unit Reconnect the center or side thermistor harness of the fuser unit. 2 Connection failure of the heater harness of the fuser unit Reconnect the heater harness of the fuser unit. 3 Connection failure of the eject sensor PCB harness Reconnect the eject sensor PCB harness. 4 Connection failure of the lowvoltage power supply PCB harness Reconnect the low-voltage power supply PCB harness. 5 Eject sensor PCB failure Replace the eject sensor PCB ASSY. 6 Fuser unit failure Replace the fuser unit. 7 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY. 8 Main PCB failure Replace the main PCB ASSY.
Code: 050C
Description:
When the center thermistor of the fuser unit was higher than the idle temperature, the side thermistor detected a temperature lower than the specified temperature.
Remedy:
<User Check> • Turn OFF the power switch. After several seconds, turn ON the power again and check that this error is reset.
1 Connection failure of the center or side thermistor harness of the fuser unit Reconnect the center or side thermistor harness of the fuser unit. 2 Connection failure of the heater harness of the fuser unit Reconnect the heater harness of the fuser unit. 3 Connection failure of the eject sensor PCB harness Reconnect the eject sensor PCB harness. 4 Connection failure of the lowvoltage power supply PCB harness Reconnect the low-voltage power supply PCB harness. 5 Eject sensor PCB failure Replace the eject sensor PCB ASSY. 6 Fuser unit failure Replace the fuser unit. 7 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY. 8 Main PCB failure Replace the main PCB ASSY.
Code: 0900
Description:
Detected irregular power supply for more than 100 times.
Remedy:
1 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY. Refer to “Reset irregular power supply detection counter of low-voltage power supply PCB (Function code 88)” to reset the irregular power supply detection counter after the replacement. 2 Main PCB failure Replace the main PCB ASSY.
Note: The irregular power supply detection error (Error code 0900) of the low-voltage power supply PCB occurs when there is a large distortion in the power supply voltage supplied to the machine. In this case, if the same power supply is used, the same error might occur again even if the low-voltage power supply PCB ASSY is replaced. For this reason, be sure to ask the user to rearrange the installation environment.
Code: 0A02
Description:
Detected a fan failure.
Remedy:
1 Connection failure of the fan harness Reconnect the fan harness. 2 Connection failure of the highvoltage power supply PCB harness Reconnect the high-voltage power supply PCB harness. 3 Fan failure Replace the fan. 4 High-voltage power supply PCB failure Replace the high-voltage power supply PCB ASSY. 5 Main PCB failure Replace the main PCB ASSY.
Code: 0B01
Description:
An error occurred in the high-voltage power supply PCB ASSY while operating.
Remedy:
<User Check> • Slide the green tab of the drum unit to left and right for two to three times to clean the corona wire. • There is a possibility of condensation. Leave the front and back cover open for at least 30 minutes when the power is ON. Close those covers and turn the power switch OFF and then back ON again.
1 Dirt on the machine, the drum unit, the toner cartridge and the toner box terminal Clean the machine, the drum unit, the toner cartridge and the toner box terminal. 2 Connection failure of the highvoltage power supply PCB harness Reconnect the high-voltage power supply PCB harness. 3 High-voltage power supply PCB failure Replace the high-voltage power supply PCB ASSY. 4 Main PCB failure Replace the main PCB ASSY.
Code: 0B02
Description:
An error occurred in the high-voltage power supply PCB ASSY when the machine was in the ready state.
Remedy:
<User Check> • Slide the green tab of the drum unit to left and right for two to three times to clean the corona wire. • There is a possibility of condensation. Leave the front and back cover open for at least 30 minutes when the power is ON. Close those covers and turn the power switch OFF and then back ON again.
1 Dirt on the machine, the drum unit, the toner cartridge and the toner box terminal Clean the machine, the drum unit, the toner cartridge and the toner box terminal. 2 Connection failure of the highvoltage power supply PCB harness Reconnect the high-voltage power supply PCB harness. 3 High-voltage power supply PCB failure Replace the high-voltage power supply PCB ASSY. 4 Main PCB failure Replace the main PCB ASSY.
Code: 2200
Description:
Cartridge sensor detected that the incompatible toner cartridge was installed.
Remedy:
<User Check> • Replace with a toner cartridge which has a correspondent capacity.
1 Main PCB failure Replace the main PCB ASSY.
Code: 2400
Description:
Toner cartridge is not recognized by the cartridge sensor.
Remedy:
<User Check> • Replace with a toner cartridge which has a correspondent capacity.
1 Main PCB failure Replace the main PCB ASSY.
Code: 2500
Description:
Toner cartridge could not communicate with the cartridge sensor.
Remedy:
<User Check> • Replace with a toner cartridge which has a correspondent capacity.
1 Main PCB failure Replace the main PCB ASSY.
Code: 2E00
Description:
Could not communicate with the cartridge sensor on the machine side.
Remedy:
<User Check> • Replace with a toner cartridge which has a correspondent capacity.
1 Main PCB failure Replace the main PCB ASSY.
Code: 3A00
Description:
A communication error occurred between the controller and engine in main PCB.
Remedy:
1 Main PCB failure Replace the main PCB ASSY.
Code: 4000
Description:
Number of the drum unit rotations reaches the upper limit soon.
Remedy:
<User Check> • Prepare a new drum unit.
1 If the error display is not cleared after the drum unit in the toner box model has been replaced with a new one. Refer to “Resetting Drum Counter” and perform the manual new drum detection. 2 Replace the drum unit with a new one and reset the drum counter. If the error display is not cleared, the main PCB is faulty. Replace the main PCB ASSY.
Code: 4200
Description:
Number of the drum unit rotations has reached the upper limit. (Printing does not stop.)
Remedy:
<User Check> • Prepare a new drum unit.
1 If the error display is not cleared after the drum unit in the toner box model has been replaced with a new one. Refer to “Resetting Drum Counter” and perform the manual new drum detection. 2 Replace the drum unit with a new one and reset the drum counter. If the error display is not cleared, the main PCB is faulty. Replace the main PCB ASSY.
Code: 4B01
Description:
Dot counter of the toner cartridge or develop roller counter reaches the upper limit soon.
Remedy:
<User Check> • Prepare a new toner cartridge.
1 Main PCB failure Replace the main PCB ASSY.
Code: 4B06
Description:
The amount of toner supplied of the toner box reaches the upper limit soon.
Remedy:
<User Check> • Prepare a new toner cartridge.
1 Main PCB failure Replace the main PCB ASSY.
Code: 4C01
Description:
Dot count or develop roller counter of the toner cartridge in models without toner box has reached the upper limit in the toner stop mode.
Remedy:
<User Check> • Replace the toner cartridge whose counter reached the upper limit.
1 Replace the toner cartridge or toner box with a new one and reset the toner counter. If the error display is not cleared, the main PCB is faulty. Replace the main PCB ASSY.
Code: 4C06
Description:
The amount of toner supplied of the toner box has reached the upper limit.
Remedy:
<User Check> • Replace the toner cartridge whose counter reached the upper limit.
1 Replace the toner cartridge or toner box with a new one and reset the toner counter. If the error display is not cleared, the main PCB is faulty. Replace the main PCB ASSY.
Code: 4D01
Description:
Dot count or develop roller counter of the toner cartridge in models without toner box is reaching the upper limit in the continuous printing mode.
Remedy:
<User Check> • Replace the toner cartridge whose counter reached the upper limit.
1 Replace the toner cartridge or toner box with a new one and reset the toner counter. If the error display is not cleared, the main PCB is faulty. Replace the main PCB ASSY.
Code: 4E01
Description:
Toner cartridge in models without toner box has reached the upper limit in the continuous printing mode.
Remedy:
<User Check> • Replace the toner cartridge whose counter reached the upper limit.
1 Replace the toner cartridge or toner box with a new one and reset the toner counter. If the error display is not cleared, the main PCB is faulty. Replace the main PCB ASSY.
Code: 4F01
Description:
The new toner sensor of the toner cartridge could not detect a new cartridge properly.
Remedy:
<User Check> • Replace the toner cartridge with a new toner cartridge again. • If the machine is on the uneven surface, place it on a level surface.
1 Connection failure of the new toner sensor PCB harness Reconnect the new toner sensor PCB harness. 2 New toner actuator coming off or caught in some sections of the machine Reattach the new toner actuator. 3 New toner sensor failure Replace the new toner sensor PCB ASSY. 4 Main PCB failure Replace the main PCB ASSY.
Code: 4F05
Description:
New process sensor could not detect the new drum unit correctly.
Remedy:
<User Check> • Replace the drum unit with a new drum unit again. • If the machine is on the uneven surface, place it on a level surface.
1 High-voltage power supply PCB failure Replace the high-voltage power supply PCB ASSY. 2 Main PCB failure Replace the main PCB ASSY.
Code: 5E00
Description:
New toner box sensor could not detect the new toner box correctly.
Remedy:
<User Check> • Replace the toner box with a new toner box again. • If the machine is on the uneven surface, place it on a level surface.
1 New toner box sensor failure Replace the high-voltage power supply PCB ASSY. 2 Main PCB failure Replace the main PCB ASSY.